Accessibility Skip to content
Article ID: 000031989
Last Modified Date: 12/10/2021
Access Level: Public

Voyager 510S/510SL/510SL+: Density

As a guide, we recommend a maximum of 8 simultaneous users (active calls) in a typical 50ft x 65ft office.
Obviously more than 10 systems may be deployed as long as no more than 8 calls are in progress at any one time. This assumes that there are no other active Bluetooth or other 2.4GHz devices (i.e WiFi/802.11) operating within the area. Even with Voyagers Adaptive Frequency Hopping (AFH), WiFi/802.11 can reduce the amount of available spectrum and impact density.
  As a guide, the number of users may be increased by 50% for each doubling of floor size. For example:
  • 50ft x 65ft office = 8 active calls
  • 100ft x 65ft office = 8 + 50% of 8 = 8 + 4 = 12 active calls
  • 100ft x 130ft office = 12 + 50% of 12 = 12 + 6 = 18 active calls
  Note: These are estimations only and are subject to revision on completion of user density trials.   What happens if the recommended number of Voyager 510s systems is exceeded? When the recommended number of Voyager 510s systems for the given environment is exceeded, users may experience a degradation of audio quality.