PRCS: How to configure debugging for the Osprey 230 card

PRCS:  How to configure debugging for the Osprey 230 card
1.  Launch Osprey Config      a.  Double-click on Video Filter 1      b.  Click on the Device tab      c.  Under Diagnostic Logging, check the "Enable' checkbox      d.  Click on Apply to save your changes. 2.  Next, download DebugView
3.  In DebugView go to the Capture menu:
     a.  Disable Capture Win32
     b.  Enable Capture Kernel
     c.  Enable "Enable Verbose Kernel Ouput"
    
      NOTE:   Keep "Pass Through"
                   Keep "Capture Events" 4.  Go to File menu:
     a. Save Log file as:
     b. Browser to location to save
     c.  Enter filename
     d. Select "Limit Log Size" ; Max Log Size (MB); select Wrap. Keep it running in the background.  If the unit is rebooted, you
must re-set the configurations again. Recommend not to reboot the unit.